Show/Hide TOC

MT 524 Field Specifications

5. Field 99B: Number Count

FORMAT

Option B :4!c//3!n (Qualifier)(Number)

PRESENCE

Optional in mandatory sequence A

QUALIFIER

(Error code(s): T89)

Order M/O Qualifier R/N CR Options Qualifier Description
1 O SETT N C3 B Current Instruction Number
2 O TOSE N   B Total of Linked Instructions

DEFINITION

This qualified generic field specifies:

SETT Current Instruction Number Sequential number of the instruction in a range of linked instructions.
TOSE Total of Linked Instructions Total number of instructions that are linked together.

USAGE RULES

The current instruction number must be specified when the Sender wants to indicate that this instruction is linked to one or more instructions.