Show/Hide TOC

MT 300 Field Specifications

83. Field 98G: Confirmation Timestamp

FORMAT

Option G 8!n6!n[,3n][/[N]2!n[2!n]] (Date)(Time)(Decimals)(UTC Indicator)

PRESENCE

Optional in optional sequence E

DEFINITION

This field specifies the date and time of the confirmation of the trade in Coordinated Universal Time (UTC)

NETWORK VALIDATED RULES

Date must be a valid date expressed as YYYYMMDD (Error code(s): T50).

Time must be a valid time expressed as HHMMSS (Error code(s): T38).

UTC Indicator must be a valid time expressed as HH[MM] (Error code(s): T39).