MT 306 Field Specifications

61. Field 37U: Trigger Level

FORMAT

Option U 12d (Rate)

PRESENCE

Mandatory in a conditional sequence (C10)

DEFINITION

This field specifies the trigger level. For double triggers, this field specifies the upper level.

NETWORK VALIDATED RULES

The integer part of Rate must contain at least one digit. A decimal comma is mandatory and is included in the maximum length (Error code(s): T40, T43).